Sensors
SEN-03
Thermometer sensor with flexibile head
Order number: SEN-09
SEN-03_SEN-09 |
Felxibile head:
- Order number: SEN-09-01
- n1,5mm pipe; long: 300mm; connektor: Spec 3p
Extension cable
- Order number: CAB-58
- Long: 2m; Connector: Spec 3p and n6,3 Jack
|
Accessories
MAP sensor family.
(Extracelluláris monofázisú potenciál)
Material of body: PMMA
Material of sensors segment: Platina
Lenght of the built in cable: ~ 150 mm
The connektor: SPEC-10, female
Az adapter forgatásával optimális pozícióba állítható a MAP sensor
Accessories - MAP sensor family |
Accessory
- Extension cable (product code: CAB-061)
- Adaptor (depending of used Langendorff
equipment, see bellow)
|
Product code
(For all MDE Langendorff equipment, except LF-13, see below) SEN-13-01 MAP sensor for rat heart SEN-13-02 MAP sen sor for rat heart in SEN-13-03 MAP sensor for guinea-pig heart in
For LF-13 equpment: SEN-13-06 MAP sensor for rat heart SEN-13-07 MAP sensor for guinea-pig heart SEN-13-08 MAP sensor for rabit heart
|
Accessories - MAP sensor family |
Spare parts
Standart adaptor for heart chamber (product code: LF-10-68) SEN-13-11 Adaptor for SEN-13-06 SEN-13-12 Adaptor for SEN-13-07 SEN-13-13 Adaptor for SEN-13-08 SEN-13-14 |
EEG adapter (korona)
EEG adapter |
EEG adapter - SEN-14-01
|
EEG adapter - SEN-14-01 |
EEG adapter - SEN-14-04 |
SEN-14-01 2ch |
SEN-14-02 4ch |
SEN-14-04 4ch |
Inplantable myographical sensors
The sensors are made with silver thread (0,2mm), or Ag/AgCl electrode (Ø4mm), or combination of them.
The combinated sensor pairs always contain one silver thread and one Ag/AgCl electrode.
Sensor with one pair of elektrodes
|
Product code
|
Inplantable myographical sensors - SEN-15-11 |
SEN-15-11
|
05 sensor b |
SEN-15-15
|
05 sensor c |
SEN-15-13
|
Sensor with two pair of electrodes
|
|
Inplantable myographical sensors - SEN-15-12 |
SEN-15-12
|
Inplantable myographical sensors - SEN-15-16 |
SEN-15-16
|
Inplantable myographical sensors - SEN-15-14 |
SEN-15-14
|
Inplantable myographical sensors - SEN-15-14 |
SEN-15-14
|
The procedure of connecting the implantable
myographical sensors:
General principles:
- The first sensor pair is always connected to the 1st and 2nd pin of the socket.
- The second sensor pair is always connected to the 3rd and 4th pin of the socket.
|
08 sensor |
SEN-15-15 SEN-15-16
|
The Ag/AgCl electrode are always connected to the 1st and 3th pin of the socket. |
SEN-15-12
|
|
The red wire pair always belongs to the first sensor pair. |
|
SEN-15-12 SEN-15-14 SEN-15-16 SEN-15-17
|
|
Inplantable myographical sensors
|
|
Media